Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A

Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
R1,177
The ACT Extension lead PDU 19" C14 IEC60320 with 8 type F sockets (3 m H05VV-F 3G1.0) is a 1U rack-mountable power distribution unit designed for network cabinets and server racks. It provides eight grounded angled outlets and a three-metre supply cable with a C14 connector. The unit features therma... Read More
Stock 274 Code 2411355 Brand ACT Model PD3004 Warranty 2 Years

Shipping & Returns

Estimated delivery Thursday, October 8
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

The ACT Extension lead PDU 19" C14 IEC60320 with 8 type F sockets (3 m H05VV-F 3G1.0) is a 1U rack-mountable power distribution unit designed for network cabinets and server racks. It provides eight grounded angled outlets and a three-metre supply cable with a C14 connector. The unit features thermal overload protection with a reset button, multi-position mounting brackets and all necessary mounting hardware.

Advantages

The aluminium-housed PDU offers eight 45° angled grounded type F sockets with child protection and red colouring for easier identification of critical loads, especially when paired with a UPS. Built-in thermal overload protection (2500 W / 10 A) with a reset button improves safety, while the included 3 m H05VV-F 3G1.0 cable with C14 connector simplifies installation. Multi-angled mounting brackets and supplied cage nuts, screws and plastic washers allow flexible positioning in a 1U 19" rack.

Suitable for

When it may not be suitable

This PDU is rated for a maximum of 2500 W and 10 A; it is not suitable where higher power or higher current capacity is required. It is designed for indoor use and for installation in 19" 1U racks, so it is not appropriate for standalone floor use or environments that need weatherproof or outdoor-rated equipment.

Key specifications

How to use

Mount the PDU into a 1U space in a 19" rack using the supplied mounting brackets and hardware; the brackets allow multiple mounting positions to suit your rack layout. Connect the 3 m C14 cable to a compatible mains inlet or UPS output and distribute power to rack devices via the eight angled sockets. If the overload protection trips, press the reset button after resolving the overload condition.

What to consider before purchase

Recommendations

Distribute high-draw devices across multiple PDUs or phases where possible and monitor combined load to avoid tripping the thermal overload. Use the red outlets to designate UPS-backed equipment for clearer cable management and quick identification during maintenance.
Key Highlights
  • Powering servers, switches and other rack-mounted IT equipment in 19" 1U racks
  • Use in network cabinets and small server rooms where space is limited
  • Racks that require clearly identified UPS-protected outlets
  • Form factor: 19" 1U rack-mount PDU
  • Number of outlets: 8 grounded type F sockets, 45° angled, child-protected
  • Cable: 3 m H05VV-F 3G1.0 with C14 connector
  • Maximum input power: 2500 W
  • Maximum current: 10 A
  • Input voltage: 230 V AC
  • Thermal overload protection with reset button
  • Housing material: aluminium
  • Colour: black housing with red outlets
  • Intended placement: indoor, rack-mounted
  • Ensure total connected load does not exceed 2500 W / 10 A
  • Confirm compatibility of type F outlets and C14 input with your equipment and mains/UPS connectors
  • Verify you have a 1U free space in a 19" rack for installation
  • Indoor installation only — not suitable for outdoor or wet environments
Specifications
AC input voltage
230 V
AC outlet types
Type F
AC outlets quantity
8 AC outlet(s)
Cable length
3 m
Child protection
Yes
Indication light
Yes
Maximum current
10 A
Maximum input power
2500 W
On/off switch
No
Placement supported
Indoor
Power plug form factor
Straight
Power plug type
C14 coupler
Product colour
Black, Red
Warranty period
5 year(s)

Leaflet

Open Leaflet
Price history over the last 6 months
Power distribution unit ACT PD3004 19 inch C14 IEC60320 with 8 Type F sockets, 3 m H05VV-F 3G1.0, 230 V 10 A
Current
R1,177
Lowest
R1,050
Highest
R1,177
Change 24H
+R15   +1%
Week
+R127   +12%
Month
+R127   +12%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.