Account Contact
Your Cart
Pay the courier with no extra fees.
Need help? DistriNode AI can handle any task on our site.

DEHN SET 3 DSH ZP B2 LSG 909657 Combined Lightning Current and Surge Arrester Set Type 1+2, 3+1 Poles, TT/TN-S, 230/400 V

DEHN SET 3 DSH ZP B2 LSG 909657 Combined Lightning Current and Surge Arrester Set Type 1+2, 3+1 Poles, TT/TN-S, 230/400 V
DEHN SET 3 DSH ZP B2 LSG 909657 Combined Lightning Current and Surge Arrester Set Type 1+2, 3+1 Poles, TT/TN-S, 230/400 V
R6,466
The DEHN SET 3 DSH ZP B2 LSG 909657 is a combined lightning current and surge arrester set for main power supply systems, pre-metering areas, and metering panels. It combines Type 1 and Type 2 protection in a single spark-gap-based device, suitable for TT and TN-S earthing systems.HighlightsCombined... Read More
Stock 12 Code 3508019 Brand DEHN + SOEHNE Model 909657 Warranty 2 Years

Shipping & Returns

Estimated delivery Tuesday, October 6
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

The DEHN SET 3 DSH ZP B2 LSG 909657 is a combined lightning current and surge arrester set for main power supply systems, pre-metering areas, and metering panels. It combines Type 1 and Type 2 protection in a single spark-gap-based device, suitable for TT and TN-S earthing systems.

Highlights

  • Combined Type 1 + Type 2 (Class I + II) protection per IEC/EN 61643-11
  • 3+1 pole configuration (3 phase + neutral) for 230/400 V AC systems
  • High discharge capacity: Iimp 7 kA (10/350 µs) per pole, Imax 50 kA (8/20 µs) per pole
  • Low voltage protection level Up ≤ 1.5 kV
  • Follow current extinguishing capability 50 kA rms
  • Mounts on 35 mm DIN rail, IP20, operating temperature -40 °C to +80 °C

In daily use

This set is installed in the main power supply system, typically before the meter, to protect downstream equipment from lightning currents and surges. It requires an external upstream fuse; no integrated fuse or status indication is provided.

Full specifications

  • Earthing system: TT, TN-S
  • Nominal voltage: 230 / 400 V AC
  • Max. continuous operating voltage (Uc): 255 V AC
  • Nominal discharge current (In): 20 kA per pole (8/20 µs)
  • Max. discharge current (Imax): 50 kA per pole (8/20 µs)
  • Impulse current (Iimp): 7 kA per pole (10/350 µs)
  • Voltage protection level (Up): ≤ 1.5 kV
  • Follow current extinguishing capability (Ifi): 50 kA rms
  • Short-circuit withstand capability (Isccr): 50 kA rms (with suitable upstream fuse)
  • Number of poles: 3+1
  • Mounting: 35 mm DIN rail
  • Operating temperature: -40 °C to +80 °C
  • Degree of protection: IP20
  • Standards: IEC 61643-11, EN 61643-11
  • Technology: Spark-gap-based
  • Integrated fuse: No
  • Status indication: No

Final note

DEHN SET 3 DSH ZP B2 LSG 909657 is a robust solution for lightning and surge protection in TT and TN-S systems, ensuring reliable protection for electrical installations.

Specifications
Brand
DEHN + SOEHNE
Category
Surge Protection Device
Certification
IEC 61643-11, EN 61643-11
Compatibility
TT, TN-S earthing systems
Compliance certificates
IEC 61643-11, EN 61643-11
EAN
4013364562769
Input current
20 kA (8/20 µs) per pole
Input voltage
230 / 400 V AC
Model
SET 3 DSH ZP B2 LSG
MPN
909657
Output voltage
≤ 1.5 kV
Weight
1 kg
Price history over the last 6 months
DEHN SET 3 DSH ZP B2 LSG 909657 Combined Lightning Current and Surge Arrester Set Type 1+2, 3+1 Poles, TT/TN-S, 230/400 V
Current
R6,466
Lowest
R6,452
Highest
R6,466
Change 24H
+R14   +0%
Week
—   
Month
—   

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.