Account Contact
Your Cart
Pay the courier with no extra fees.
Need help? DistriNode AI can handle any task on our site.

APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black

APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
R4,646
APC Basic Rack PDU provides reliable rack-mounted power distribution for data center and network equipment. It accepts nominal input voltages of 120, 208 or 230 V and delivers corresponding output voltages with twelve always-on outlets: ten IEC-320 C13 and two IEC-320 C19. The unit is designed for 1... Read More
Stock 3 Code 773683 Brand APC Model AP9559 Warranty 2 Years

Shipping & Returns

Estimated delivery Thursday, October 1
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

APC Basic Rack PDU provides reliable rack-mounted power distribution for data center and network equipment. It accepts nominal input voltages of 120, 208 or 230 V and delivers corresponding output voltages with twelve always-on outlets: ten IEC-320 C13 and two IEC-320 C19. The unit is designed for 19-inch racks with vertical mounting capability and includes cord retention clips and rack mounting brackets.

Advantages

The APC Basic Rack PDU offers a cost-effective solution for power distribution in rack environments, supporting multiple nominal voltages and a wide acceptable input range (90–250 VAC). With an IEC-320 C20 input connector and a 2.5 m (8.2 ft) cord, it simplifies installation while providing overload protection and a maximum per-phase current rating of 16 A.

Key specifications

  • Output voltage(s): 120, 208, 230 V
  • Output connections: (10) IEC-320 C13, (2) IEC-320 C19
  • Always-on outlets: 12
  • Maximum total/current per phase: 16 A
  • Input connection: IEC-320 C20
  • Nominal input voltage: 120 / 208 / 230 V
  • Acceptable input voltage: 90–250 VAC
  • Input frequency: 50/60 Hz
  • Cord length: 2.5 m (8.2 ft)
  • Load capacity: 3680 W
  • Mounting: 19-inch rack, vertical mounting capable

How to use

Mount the PDU vertically in a 19-inch equipment rack using the supplied rack mounting brackets and secure the power cord with the included cord retention clips. Connect the IEC-320 C20 input to an appropriate power source matched to the device's nominal or acceptable input voltage range. Attach equipment to the IEC-320 C13 and C19 outlets; all twelve outlets are always on. Observe the maximum per-phase current of 16 A to avoid tripping overload protection.

Recommendations

Verify facility power capacity and circuit ratings before installation, and distribute connected loads to avoid exceeding 16 A per phase. Use compatible IEC power cords and ensure rack airflow is not obstructed to maintain equipment cooling.

Key Highlights
  • Output voltage(s): 120, 208, 230 V
  • Output connections: (10) IEC-320 C13, (2) IEC-320 C19
  • Always-on outlets: 12
  • Maximum total/current per phase: 16 A
  • Input connection: IEC-320 C20
  • Nominal input voltage: 120 / 208 / 230 V
  • Acceptable input voltage: 90–250 VAC
  • Input frequency: 50/60 Hz
  • Cord length: 2.5 m (8.2 ft)
  • Load capacity: 3680 W
  • Mounting: 19-inch rack, vertical mounting capable
Specifications
AC outlet types
C13 coupler, C19 coupler
AC outlets quantity
12 AC outlet(s)
Cable length
2.5 m
Depth
57.2 mm
Height
44.5 mm
I/O ports
Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Input Connection Type - IEC-320 C20
Load capacity
3680 VA
Maximum input current per phase
16 A
Maximum power
3680 W
Mounting
Horizontal/Vertical
Operating relative humidity (H-H)
0 - 95%
Operating temperature (T-T)
0 - 45 °C
PDU types
Basic
Power plug
C20 coupler
Product colour
Black
Rack capacity
0U/1U
Storage relative humidity (H-H)
0 - 95%
Storage temperature (T-T)
-25 - 65 °C
Type
Single-phase
Weight
980 g
Width
447 mm

Leaflet

Open Leaflet
Price history over the last 6 months
APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
Current
R4,646
Lowest
R4,142
Highest
R8,192
Change 24H
+R465   +11%
Week
+R504   +12%
Month
-R2,892   -38%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.