Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions

Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
R2,188
ATEN EA1640 is an indoor temperature and humidity sensor designed for environmental monitoring in enclosed spaces. It measures temperature between −10 °C and 75 °C and monitors relative humidity across the full 0–100% range. The compact housing (35.7 × 104.4 × 21.4 mm) and included 1.5 m RJ-45 cable... Read More
Stock 2 Code 1457495 Brand ATEN Model EA1640-AT Warranty 2 Years

Shipping & Returns

Estimated delivery Tuesday, October 6
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

ATEN EA1640 is an indoor temperature and humidity sensor designed for environmental monitoring in enclosed spaces. It measures temperature between −10 °C and 75 °C and monitors relative humidity across the full 0–100% range. The compact housing (35.7 × 104.4 × 21.4 mm) and included 1.5 m RJ-45 cable, magnet and rack-mount kits allow flexible placement inside server racks, equipment cabinets, offices and other controlled environments. The EA1640 integrates with ATEN PG series PDUs and supports daisy-chaining up to eight devices for expanded coverage.

Advantages

The EA1640 provides reliable, precise environmental readings compatible with ATEN PG PDU systems and a range of ATEN environmental sensors. Temperature accuracy is specified to ±1 °C within the 10–40 °C range and ±1.5 °C outside that band; relative humidity accuracy is ±7.5 % RH in the 30–70 % RH band and broader tolerances at lower and higher humidity levels. Multiple interfaces (RJ-45 input/output and RJ-11) and a terminal block support connections to door and leakage sensors, enabling consolidated monitoring. Compact dimensions, magnetic attachment and rack-mount accessories simplify installation in constrained spaces.

Suitable for

  • Server rooms and data centers for environmental monitoring and asset protection
  • Equipment racks and cabinets where space is limited
  • HVAC and climate-control verification in offices and green buildings
  • Healthcare and laboratory areas requiring routine temperature and humidity logging
  • Smart factories and industrial sites that integrate sensor data with power distribution units

Key specifications

  • Temperature measuring range: −10 °C to 75 °C
  • Temperature accuracy: ±1 °C (10–40 °C); ±1.5 °C (−10–10 °C, 40–75 °C)
  • Humidity measuring range: 0–100 % RH
  • Humidity accuracy: ±7.5 % RH (30–70 % RH); ±15 % RH (15–40 % RH, 70–90 % RH)
  • Interfaces: 1 × RJ-45 input, 1 × RJ-45 output, 1 × RJ-11 input, 1 × terminal block for external sensors
  • Daisy-chain support: up to 8 devices
  • Enclosure dimensions: 35.7 × 104.4 × 21.4 mm
  • Included accessories: 1.5 m RJ-45 cable, magnet for metallic surfaces, rack-mount kits
  • Indoor use
  • LED indicator visible through enclosure

How to use

Connect the EA1640 to an ATEN PG series PDU using the RJ-45 input port and, if required, daisy-chain additional EA1640 units via the RJ-45 output. Use the RJ-11 input or terminal block to attach compatible environmental, door or leakage sensors. Place the sensor at the monitoring point using the supplied 1.5 m cable, attach it to a metallic surface with the built-in magnet or secure it inside a rack with the included mount kit. Verify readings through the PDU management interface and set alert thresholds there when supported.

Recommendations

Install the EA1640 away from direct heat sources, ventilation outlets or water ingress points to ensure representative measurements. For critical installations, position sensors at the locations that reflect device intake air or room center points and validate sensor readings against a calibrated reference during initial setup. Limit daisy-chain length and device count according to installation guidelines to preserve signal integrity.

Key Highlights
  • A humidity and temperature measuring solution for ATEN PG PDU series
  • Precise relative humidity accuracy: ±7.5 % RH, 30 – 70 % RH; ±15 % RH, 15 – 40 % RH, 70 – 90 % RH
  • Highly accurate temperature measuring: ±1 °C (Max.), 10 – 40 °C; ±1.5 °C (Max.), –10 – 10 °C, 40 – 75 °C
  • Supports up to 8 daisy-chained devices
  • Multiple interfaces to broaden applications –
  • – 1 x RJ-45 input port, 1 x RJ-45 output port, and 1x RJ-11input port support connection with PG PDU series and EA1140 / EA1240 / EA1340 environmental sensors
  • – 1 x terminal block supports EA1440 / EA1441 / EA1442 door sensor and EA1540 capacitive leakage sensor
  • Meets flexible installation purposes –
  • – Included 1.5 m RJ-45 cable for ideal location placement
  • – Contains a magnet for sticking to metallic surfaces
  • – Included rack mount kits enable quick installation inside racks
  • Overload protection prevents overheating of the protected equipment
  • LED indicator is visible through the enclosure
  • Prevents device malfunctions thanks to early detection in case of overheating / excessive humidity
  • Suitable for applications that require precise measuring, such as server rooms, data centers, hospitals, smartfactories, and green offices
  • Temperature & humidity sensor
  • Indoor
  • Temperature measuring range: -10 - 75 °C
  • Humidity measuring range: 0 - 100%
  • Standard interfaces: RJ-11
Specifications
Accuracy
15 %
Cable length
1.5 m
Certification
EMC/FCC, Class A
Country of origin
Taiwan
Depth
104.4 mm
Harmonized System (HS) code
90258040
Height
21.4 mm
Humidity measuring range
0 - 100
LED indicators
Y
Master (outer) case gross weight
4980 g
Master (outer) case height
292 mm
Master (outer) case length
470 mm
Master (outer) case width
270 mm
Operating relative humidity (H-H)
0 - 80
Operating temperature (T-T)
-10 - 75
Package depth
124 mm
Package height
129 mm
Package weight
170 g
Package width
42 mm
Ports quantity
2
Purpose
Indoor
Sensor type
Temperature & humidity sensor
Standard interfaces
RJ-11
Storage temperature (T-T)
-20 - 75
Temperature measuring range
-10 - 75
Weight
0.05 kg
Width
35.7 mm

Document

Open Document

Leaflet

Open Leaflet

Document

Open Document
Price history over the last 6 months
Indoor temperature and humidity sensor ATEN EA1640 — -10 to 75 °C, compact dimensions
Current
R2,188
Lowest
R2,145
Highest
R2,309
Change 24H
+R39   +2%
Week
-R43   -2%
Month
-R48   -2%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.