Account Contact
Your Cart
Pay the courier with no extra fees.
Need help? DistriNode AI can handle any task on our site.

Duplex LWL Patch Cable BlueOptics B2PB-BO LC-UPC to LC-UPC 3 m Multimode OM4 50/125 µm, ≤0.2 dB insertion loss, ceramic ferrule, test report

Duplex LWL Patch Cable BlueOptics B2PB-BO LC-UPC to LC-UPC 3 m Multimode OM4 50/125 µm, ≤0.2 dB insertion loss, ceramic ferrule, test report
Duplex LWL Patch Cable BlueOptics B2PB-BO LC-UPC to LC-UPC 3 m Multimode OM4 50/125 µm, ≤0.2 dB insertion loss, ceramic ferrule, test report
R556
Duplex multimode LWL patch cable BlueOptics B2PB-BO with LC‑UPC connectors on both ends provides a 3 m OM4 50/125 µm fiber link for short-range, high-bandwidth multimode network connections. The cable uses a ceramic ferrule and is factory-tested to ensure insertion loss ≤0.2 dB, supplied with a test... Read More
Stock 1956 Code 2356524 Brand BLUEOPTICS Model B2PB-BO Warranty 2 Years

Shipping & Returns

Estimated delivery Tuesday, October 6
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

Duplex multimode LWL patch cable BlueOptics B2PB-BO with LC‑UPC connectors on both ends provides a 3 m OM4 50/125 µm fiber link for short-range, high-bandwidth multimode network connections. The cable uses a ceramic ferrule and is factory-tested to ensure insertion loss ≤0.2 dB, supplied with a test report that documents measured performance. It is intended for structured cabling in data centers, server racks and campus distribution where low loss and consistent multimode transmission are required.

Advantages

The cable combines OM4 multimode fiber performance with LC‑UPC duplex connectors to support high data rates and reliable modal bandwidth. A ceramic ferrule maintains connector endface stability and repeatable mating performance. Factory measurement and an included test report verify insertion loss levels below or equal to 0.2 dB, enabling predictable link planning and faster installation verification.

Suitable for

Key specifications

How to use

Install the BlueOptics LC‑UPC duplex patch cable by aligning each LC connector with the adapter or transceiver port and inserting until it clicks into place. Route the cable following standard bend radius and strain relief practices for multimode patch cords to avoid microbends and excess attenuation. For removal, depress the connector latch and withdraw straight out to prevent damage to the ferrule endface. Verify connections using the supplied test report and, if required, perform a visual inspection or light-level test before putting the link into service.

Recommendations

Keep connector endfaces clean and protected with dust caps until final connection. Avoid tight bends and compressive forces near the connector boot. Use appropriate fiber cleaning tools and perform endface inspection after installation to maintain low insertion loss and long-term link stability.

Key Highlights
  • Data center horizontal and rack-to-rack connections
  • Campus backbone and building distribution
  • Short-range multimode links for switches, transceivers and patch panels
  • High-density LC panel installations
  • Fiber type: Multimode OM4, 50/125 µm
  • Connector type: LC‑UPC to LC‑UPC duplex
  • Length: 3 m
  • Typical insertion loss: ≤0.2 dB (measured)
  • Ferrule material: Ceramic
  • Cable configuration: Duplex patch cord
Price history over the last 6 months
Duplex LWL Patch Cable BlueOptics B2PB-BO LC-UPC to LC-UPC 3 m Multimode OM4 50/125 µm, ≤0.2 dB insertion loss, ceramic ferrule, test report
Current
R556
Lowest
R545
Highest
R833
Change 24H
+R10   +2%
Week
-R236   -30%
Month
-R237   -30%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.