Surge Protection Device HiSmart NV821686 1P Class B 30–60 kA 385VAC

Surge Protection Device HiSmart NV821686 1P Class B 30–60 kA 385VAC
Surge Protection Device HiSmart NV821686 1P Class B 30–60 kA 385VAC
R415
HiSmart NV821686 is a single-pole (1P) surge protection device Class B designed for installation in the incoming low-voltage distribution box to protect electrical installations and connected equipment from high-energy transients and lightning-induced surges. Rated for a maximum continuous operating... Read More
Stock 5 Code 2181638 Brand CNC Model NV821686 Warranty 2 Years

Shipping & Returns

Estimated delivery Tuesday, September 29
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

HiSmart NV821686 is a single-pole (1P) surge protection device Class B designed for installation in the incoming low-voltage distribution box to protect electrical installations and connected equipment from high-energy transients and lightning-induced surges. Rated for a maximum continuous operating voltage of 385 V AC, the device supports system types TT, IT, TN-S, TN-C and TN-C-S and complies with IEC 61643-1 and relevant GB and CE standards.

Advantages

The device provides a high maximum discharge current (Imax) of 60 kA and a nominal discharge current (In) of 30 kA, ensuring robust handling of lightning stroke currents up to 100 kA when installed correctly. With a fast response time below 25 ns and a voltage protection level (Up) of ≤2.2 kV, it limits overvoltage propagation to downstream equipment. Compact dimensions and DIN-rail (35 mm) mounting simplify installation in standard distribution boards.

Suitable for

  • Protection of residential distribution boards and main incoming lines
  • Commercial and light industrial low-voltage distribution panels
  • Systems configured as TT, IT, TN-S, TN-C and TN-C-S
  • Areas prone to lightning-induced transients

Key specifications

  • Number of poles: 1 (single-pole, 1P)
  • Class: B
  • Maximum continuous operating voltage (Uc): 385 V AC
  • Maximum discharge current (Imax): 60 kA
  • Nominal discharge current (In): 30 kA
  • Voltage protection level (Up): ≤2.2 kV
  • Response time: <25 ns
  • Frequency: 50/60 Hz
  • Operating temperature: -40 °C to +85 °C
  • Relative humidity (at 25 °C): <95%
  • Mounting: 35 mm DIN-rail
  • Wires cross-section: up to 6–10 mm²
  • Dimensions (W×H×D): 18 × 90 × 67 mm
  • Standards: IEC 61643-1, GB18802.1, GB50057, CE
  • Warranty: 24 months

How to use

Install the HiSmart NV821686 on a standard 35 mm DIN rail in the incoming line of the low-voltage distribution box according to local wiring rules and the installation diagram. Connect the device in series with the supply conductor(s) using conductors within the specified cross-section range and ensure correct earthing for optimal protection. After wiring, verify connections, restore power, and check that the unit operates within its rated conditions.

Recommendations

Use this Class B surge protector as the first stage of surge protection at the service entrance for better protection of downstream devices. Complement it with appropriate downstream Type C or D protective devices for sensitive electronics and perform periodic inspections following local electrical codes.

How to use

Install the HiSmart NV821686 on a standard 35 mm DIN rail in the incoming line of the low-voltage distribution box according to local wiring rules and the installation diagram. Connect the device in series with the supply conductor(s) using conductors within the specified cross-section range and ensure correct earthing for optimal protection. After wiring, verify connections, restore power, and check that the unit operates within its rated conditions.

Recommendations

Use this Class B surge protector as the first stage of surge protection at the service entrance for better protection of downstream devices. Complement it with appropriate downstream Type C or D protective devices for sensitive electronics and perform periodic inspections following local electrical codes.

Key Highlights
  • Protection of residential distribution boards and main incoming lines
  • Commercial and light industrial low-voltage distribution panels
  • Systems configured as TT, IT, TN-S, TN-C and TN-C-S
  • Areas prone to lightning-induced transients
  • Number of poles: 1 (single-pole, 1P)
  • Class: B
  • Maximum continuous operating voltage (Uc): 385 V AC
  • Maximum discharge current (Imax): 60 kA
  • Nominal discharge current (In): 30 kA
  • Voltage protection level (Up): ≤2.2 kV
  • Response time:
  • Frequency: 50/60 Hz
  • Operating temperature: -40 °C to +85 °C
  • Relative humidity (at 25 °C):
  • Mounting: 35 mm DIN-rail
  • Wires cross-section: up to 6–10 mm²
  • Dimensions (W×H×D): 18 × 90 × 67 mm
  • Standards: IEC 61643-1, GB18802.1, GB50057, CE
  • Warranty: 24 months
Price history over the last 6 months
Surge Protection Device HiSmart NV821686 1P Class B 30–60 kA 385VAC
Current
R415
Lowest
R401
Highest
R510
Change 24H
+R10   +2%
Week
+R13   +3%
Month
-R72   -15%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.