Residual Current Breaker HiSmart NV821907 32A 30mA

Residual Current Breaker HiSmart NV821907 32A 30mA
Residual Current Breaker HiSmart NV821907 32A 30mA
R544
HiSmart NV821907 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) rated at 32 A and 30 mA residual sensitivity. Designed for combined protection against overloads, short circuits and earth leakage, this device disconnects circuits quickly to reduce the risk of electric... Read More
Stock 5 Code 2181659 Brand CNC Model NV821907 Warranty 2 Years

Shipping & Returns

Estimated delivery Tuesday, September 29
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

HiSmart NV821907 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) rated at 32 A and 30 mA residual sensitivity. Designed for combined protection against overloads, short circuits and earth leakage, this device disconnects circuits quickly to reduce the risk of electric shock and fire in residential and small commercial installations. The unit meets IEC 61009-1 / EN 61009-1 standards and is suitable for DIN-rail mounting.

Advantages

The RCBO integrates residual-current detection and overcurrent protection in a single compact module, saving space in distribution boards. It features a clear contact position indication (red = closed, green = open), flame-retardant and high-temperature resistant housing, an anti-mistake contact terminal block and supports cable or pin-type busbar connections up to 35 mm². The device offers a rated short-circuit capacity of 6 kA and a quick break time for fast disconnection.

Suitable for

  • Protection of branch circuits in residential electrical panels
  • Small commercial installations requiring combined RCD and MCB protection
  • Circuits where space-saving DIN-rail mounted protection is needed
  • Applications requiring 32 A rated current with 30 mA earth-fault sensitivity

Key specifications

  • Number of poles: 2
  • Rated current (In): 32 A
  • Tripping characteristic: Class C
  • Rated sensitivity: 30 mA
  • Rated voltage (Ue): AC 230 V
  • Rated short-circuit capacity (Icn): 6000 A
  • Rated impulse withstand voltage (Uimp): 4000 V
  • Insulation voltage (Ui): 500 V
  • Break time: ≤ 0.1 s
  • Frequency: 50/60 Hz
  • Mechanical life: 10,000 operations; Electrical life: 4,000 operations
  • Protection class: IP20
  • Connection type: cable / pin-type busbar, top connection, up to 35 mm²
  • Mounting: DIN rail EN 60715 (35 mm)
  • Operating temperature: -25 °C to +70 °C
  • Dimensions: 82 x 36 x 78 mm
  • Standards: IEC 61009-1 / EN 61009-1

How to use

Install the HiSmart NV821907 on a standard 35 mm DIN rail inside the distribution board. Make electrical connections to the top terminals using appropriate cable or busbar up to 35 mm² and ensure correct polarity and secure tightening according to local electrical regulations. After wiring, switch the device on and test residual-current operation using a suitable RCD tester or the built-in test function, following manufacturer and regulatory instructions.

Recommendations

Use the RCBO for final circuit protection where both earth-fault detection and overcurrent protection are required. Periodically test the device (recommended monthly) and perform professional inspection and maintenance according to local standards. Do not install in environments exceeding the specified temperature range or where ingress protection IP20 is insufficient.

Key Highlights
  • Protection of branch circuits in residential electrical panels
  • Small commercial installations requiring combined RCD and MCB protection
  • Circuits where space-saving DIN-rail mounted protection is needed
  • Applications requiring 32 A rated current with 30 mA earth-fault sensitivity
  • Number of poles: 2
  • Rated current (In): 32 A
  • Tripping characteristic: Class C
  • Rated sensitivity: 30 mA
  • Rated voltage (Ue): AC 230 V
  • Rated short-circuit capacity (Icn): 6000 A
  • Rated impulse withstand voltage (Uimp): 4000 V
  • Insulation voltage (Ui): 500 V
  • Break time: ≤ 0.1 s
  • Frequency: 50/60 Hz
  • Mechanical life: 10,000 operations; Electrical life: 4,000 operations
  • Protection class: IP20
  • Connection type: cable / pin-type busbar, top connection, up to 35 mm²
  • Mounting: DIN rail EN 60715 (35 mm)
  • Operating temperature: -25 °C to +70 °C
  • Dimensions: 82 x 36 x 78 mm
  • Standards: IEC 61009-1 / EN 61009-1
Price history over the last 6 months
Residual Current Breaker HiSmart NV821907 32A 30mA
Current
R544
Lowest
R529
Highest
R632
Change 24H
+R9   +2%
Week
+R15   +3%
Month
-R59   -10%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.