APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
R45,220
The Metered Rack PDU APC NetShelter AP8886 is a 0U vertical power distribution unit designed for data center racks. It provides 42 AC outlets (30 C13 and 12 C19), supports 3-phase input up to 32 A at 400 V, and includes real-time monitoring of current, power and voltage with a 1.83 m input cable. Th... Read More
Stock 2 Code 1162481 Brand APC Model AP8886 Warranty 2 Years

Shipping & Returns

Estimated delivery Monday, October 5
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

The Metered Rack PDU APC NetShelter AP8886 is a 0U vertical power distribution unit designed for data center racks. It provides 42 AC outlets (30 C13 and 12 C19), supports 3-phase input up to 32 A at 400 V, and includes real-time monitoring of current, power and voltage with a 1.83 m input cable. The unit features a temperature/humidity sensor port, locking IEC receptacles and ultra low profile circuit breakers to help maintain reliable rack power delivery.

Advantages

The AP8886 delivers active metering for accurate power utilization data and user-defined alarm thresholds, enabling local and remote alerts to reduce the risk of circuit overload. Its compact 0U vertical form factor saves rack space while offering centralized monitoring via secure Web, SNMP or Telnet interfaces and compatibility with APC management platforms for capacity and energy efficiency planning.

Suitable for

  • Data centers and server rooms requiring per-rack power monitoring
  • Environments needing 3-phase power distribution at 400 V
  • Racks where vertical 0U mounting and high outlet density are required

Key specifications

  • Model: AP8886 (Metered Rack PDU)
  • AC outlets: 42 (30 x C13, 12 x C19)
  • Nominal input voltage: 400 V
  • Maximum current: 32 A
  • Cable length: 1.83 m
  • Weight: 8.72 kg
  • Colour: Black

How to use

Mount the AP8886 vertically in a compatible rack using the provided mounting points for 0U installation. Connect the incoming 3-phase 400 V supply to the PDU input, then plug equipment into the C13 and C19 outlets. Access monitoring and configuration through the unit’s secure Web interface, SNMP or Telnet to set alarm thresholds, view real power metrics and integrate with APC InfraStruxure management tools as required.

Recommendations

Set user-defined alarm thresholds before putting critical equipment into service, and periodically review power and temperature/humidity readings. Use the locking IEC receptacles where vibration or accidental disconnection is a concern, and integrate PDU data into centralized management for balanced loads and reduced total cost of ownership.
Key Highlights
  • Data centers and server rooms requiring per-rack power monitoring
  • Environments needing 3-phase power distribution at 400 V
  • Racks where vertical 0U mounting and high outlet density are required
  • Model: AP8886 (Metered Rack PDU)
  • AC outlets: 42 (30 x C13, 12 x C19)
  • Nominal input voltage: 400 V
  • Maximum current: 32 A
  • Cable length: 1.83 m
  • Weight: 8.72 kg
  • Colour: Black
Specifications
AC input frequency
50 - 60 Hz
AC outlet types
C13 coupler, C19 coupler
AC outlets quantity
42 AC outlet(s)
Cable length
1.83 m
Certification
EN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Compliance certificates
RoHS
Depth
51 mm
Height
1829 mm
LED indicators
Yes
Load capacity
22080 VA
Maximum current
32 A
Maximum input current per phase
32 A
Maximum power
22000 W
Monitoring
Current, Power, Voltage
Mounting
Vertical
Nominal input voltage
400 V
Nominal output voltage
230 V
Non-operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity (H-H)
5 - 95%
Operating temperature (T-T)
0 - 55 °C
Output connections
30 x IEC 320 C13 12 x IEC 320 C19
Package depth
112 mm
Package height
2050 mm
Package weight
11.6 kg
Package width
170 mm
PDU types
Metered
Power plug
IEC309
Power protection features
Overload
Product colour
Black
Rack capacity
0U
Storage relative humidity (H-H)
5 - 95%
Storage temperature (T-T)
-25 - 65 °C
Total carbon footprint (kg of CO2e)
57837.86
Weight
8.72 kg
Width
56 mm

Leaflet

Open Leaflet
Price history over the last 6 months
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
Current
R45,220
Lowest
R42,764
Highest
R45,945
Change 24H
-R432   -1%
Week
+R2,290   +5%
Month
+R2,031   +5%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.