Account Contact
Your Cart
Pay the courier with no extra fees.
Need help? DistriNode AI can handle any task on our site.

Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection

Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
R1,117
UNI-T UT18E voltage and continuity tester UNI-T UT18E voltage and continuity tester is a practical tool for quick diagnostics of electrical installations. It allows you to measure AC/DC voltages up to 1000 volts, test phase sequence, circuit continuity and operation of residual current circuit break... Read More
Stock 523 Code 1427157 Brand UNI-T Model UT18E Warranty 2 Years

Shipping & Returns

Estimated delivery Thursday, October 1
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

UNI-T UT18E voltage and continuity tester

UNI-T UT18E voltage and continuity tester is a practical tool for quick diagnostics of electrical installations. It allows you to measure AC/DC voltages up to 1000 volts, test phase sequence, circuit continuity and operation of residual current circuit breakers. It is convenient to use and at the same time provides a clear reading both on the LCD screen and with backlit LEDs.

Universal voltage measurement range

The UT18E supports up to 8 voltage levels: 6V, 12V, 24V, 50V, 120V, 230V, 400V, 690V and 1000V. It operates in both AC and DC modes, which makes it suitable for various types of installations - from domestic to industrial. The automatic polarity recognition function further helps avoid errors when diagnosing DC circuits.

Continuity measurement and RCD test

The tester allows you to check the continuity of a circuit in the range of 0 Ω to 60 kΩ, and the built-in audible signal and LED light indicate that the current is flowing correctly. The UT18E also allows you to test residual current devices (RCDs) at 230 V and 50-400 Hz, which increases the safety of the installation's use.

Additional functions to make work easier

LCD display indicates voltage in the range of 6-1000 V, and frequency in the range of 40-400 Hz. A built-in flashlight, audible signal, automatic shut-off function and silent mode make the UT18E a convenient tool. The tester is IP65-rated, which means dust and splash resistance - it will work well in construction and industrial conditions.

ManufacturerUNI-T
ModelUT18E
Voltage range (AC/DC)6V ± (1.5%+1); 12V ± (1.5%+2); 24V ± (1.5%+2); 50V ± (1.5%+3); 120V ± (1.5%+4); 230V ± (1.5%+5); 400V ± (1.5%+5); 690V ± (1.5%+5); 1000V ± (1.5%+5)
Phase rotation test100V ac~400V ac (3 phases); frequency 50/60 Hz
Continuity testResistance: 0Ω~60kΩ; sound and light indicator
RCD testOperating voltage: 230V (50~400 Hz)
Polarity detectionpositive and negative
Self-verificationLED or LCD
Power failure test100~1000V
Standby current<10μA
BacklightingYes
Silent modeYes
Overvoltage protectionYes, 1100 V
Low battery indicatorYes (approx. 2.4V)
LCD display (voltage)6V~1000V
LCD display (frequency)40 Hz ~ 400 Hz
WaterproofIP65
Weight (with batteries)277 g
Dimensions272 x 85 x 31 mm
GPSR Link: https://psr-assets.innpro.pl/tools/sg_tools_measuring_tools.pdf, Gross weight: 357, Net weight: 277, Box length: 33,00, Box width: 15,50, Box height: 3,50, Last delivery: 10.02.2026

How to use

Connect the tester probes according to the measured circuit, select the required measurement mode and read the value on the LCD or observe the LED indicators. For phase rotation check, measure between phases in a 3-phase system within 100–400 V AC and 50/60 Hz. Use the continuity function to verify circuit paths (0 Ω–60 kΩ) and listen for the audible signal or watch the LED for confirmation. To test RCDs, apply the tester function at 230 V and appropriate frequency range. Follow standard safety procedures: de-energize when required, use protective equipment and observe manufacturer recommendations.

Recommendations

Before each use, inspect probes and housing for damage, replace weak batteries (low battery indication at ~2.4 V), and avoid exposure to fluids beyond IP65 protection. Do not exceed specified overvoltage limits and consult qualified personnel for installation work beyond routine testing.

Key Highlights
  • Manufacturer: UNI-T
  • Model: UT18E
  • Voltage measurement (AC/DC): 6V ±(1.5%+1); 12V ±(1.5%+2); 24V ±(1.5%+2); 50V ±(1.5%+3); 120V ±(1.5%+4); 230V ±(1.5%+5); 400V ±(1.5%+5); 690V ±(1.5%+5); 1000V ±(1.5%+5)
  • Phase rotation test: 100 V AC–400 V AC (3-phase), 50/60 Hz
  • Continuity test: 0 Ω–60 kΩ with sound and light indicator
  • RCD test: operating voltage 230 V (50–400 Hz)
  • Polarity detection: positive and negative
  • Self-verification: LED or LCD
  • Power failure test: 100–1000 V
  • Standby current:
  • Backlighting: yes
  • Silent mode: yes
  • Overvoltage protection: up to 1100 V
  • Low battery indicator: yes (approx. 2.4 V)
  • LCD display (voltage): 6 V–1000 V
  • LCD display (frequency): 40 Hz–400 Hz
  • Waterproof rating: IP65
  • Weight (with batteries): 277 g
  • Dimensions: 272 × 85 × 31 mm
Price history over the last 6 months
Voltage and continuity tester Unit UT18E with LCD display and non-contact voltage detection
Current
R1,117
Lowest
R986
Highest
R1,156
Change 24H
+R121   +12%
Week
+R120   +12%
Month
+R129   +13%

Popular products in this category

WhatsApp
Hi, I’m DistriNode’s AI assistant. I can help you find products, compare options, create quote PDFs, or open support requests.