Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm

Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
R2,663
ABB DS202CR B16 A30 is a compact residual-current circuit breaker (RCBO) that integrates overcurrent protection with residual-current detection for single-phase circuits. The device combines a Type B trip curve with Type A residual-current sensing and a 30 mA sensitivity for human protection. It is ... Read More
Stock 45 Code 2204859 Brand ABB Model 2CSR752140R1165 Warranty 2 Years

Shipping & Returns

Estimated delivery Wednesday, October 7
You will be kept updated through our detailed tracking system
Payment options
EFTPayFastBank CardSnapScanZapperGoogle PayApple PayMobicredMoreTymePay on Arrival

ABB DS202CR B16 A30 is a compact residual-current circuit breaker (RCBO) that integrates overcurrent protection with residual-current detection for single-phase circuits. The device combines a Type B trip curve with Type A residual-current sensing and a 30 mA sensitivity for human protection. It is built for 50 Hz systems and offers a rated current of 16 A with robust short-circuit interruption capability. The module is a two-pole, two-module unit designed for DIN-rail mounting, providing coordinated protection against overloads, short circuits and earth leakage in residential and light-commercial electrical installations.

Advantages

The DS202CR B16 A30 provides combined functions in a space-saving two-module footprint, reducing the number of separate components required in a distribution board. Type B trip characteristics allow reliable protection for circuits with moderately inductive or capacitive loads, and Type A residual-current detection covers pulsating direct and alternating leakage currents. The 30 mA sensitivity offers protection against indirect and additional protection against direct contact. Its DIN-rail format and standardized dimensions simplify installation and replacement in common distribution systems.

Suitable for

Key specifications

How to use

Install the RCBO on a standardized DIN-rail inside the distribution board, ensuring the device is mounted and connected according to applicable national wiring regulations. Connect the phase and neutral conductors to the designated terminals, and ensure proper tightening of terminal screws to the torque values specified by the manufacturer's installation guide. Use the device to protect a single-phase branch circuit; verify correct operation after installation by performing a functional test using the built-in test button or an appropriate test instrument. Ensure upstream protection and coordination with other protective devices in the installation.

Recommendations

Use this RCBO where both overcurrent and earth-leakage protection are required in a single, compact device. Test the residual-current function regularly (for example, monthly) using the test button and follow local safety regulations for maintenance and periodic inspection.

Key Highlights
  • Protection of single-phase branch circuits in residential installations
  • Light-commercial electrical panels and small distribution boards
  • Circuits supplying motors, lighting, and household appliances with moderate inrush currents
  • Locations requiring combined overcurrent and earth-leakage protection with 30 mA sensitivity
  • Rated current: 16 A
  • Residual-current sensitivity: 30 mA (Type A residual detection)
  • Trip curve: Type B
  • Frequency: 50 Hz
  • Number of poles: 2 (two-pole RCBO)
  • Module width: two DIN modules
  • Dimensions (W×D×H): 36×72×86 mm
  • Interrupting capacity suitable for typical consumer distribution short-circuit levels
Specifications
Breaking capacity
6000 A
Circuit breaker type
Residual-current device
Depth
72 mm
Energy limiting class
3
Height
86 mm
Input frequency
50
Installation type
DIN-rail
International Protection (IP) code
IP20
Number of poles
2
Operating temperature (T-T)
-20 - 55
Pollution degree
3
Product colour
White
Protection class
III
Quantity per pack
1 pc(s)
Rated current
16000 A
Rated voltage
4000 V
Residual-current type
Type A
Storage temperature (T-T)
-40 - 70
Total power loss
4.2 W
Trip curve type
Type B
Weight
0.22 kg
Width
36 mm
Price history over the last 6 months
Residual-current circuit breaker ABB DS202CR B16 A30 — Type B, Type A residual, 16 A, 4000 V, 36×72×86 mm
Current
R2,663
Lowest
R2,628
Highest
R2,663
Change 24H
+R29   +1%
Week
—   
Month
—   

Popular products in this category

WhatsApp