Hensel PV Disconnection Box 70 A Mi AE 3223 3-Pole with Circuit Breaker and Grid Protection

Hensel PV Disconnection Box 70 A Mi AE 3223 3-Pole with Circuit Breaker and Grid Protection
Hensel PV Disconnection Box 70 A Mi AE 3223 3-Pole with Circuit Breaker and Grid Protection
R59,581
Photovoltaic installations require a reliable point of isolation between the generator and the grid, especially when maintenance or emergency shutdown is needed. The Hensel PV Disconnection Box 70 A Mi AE 3223 solves this by integrating a main circuit breaker and an NA-Schutz (grid and system protec... Read More
Stock Out Of StockNo Stock Code 3329208 Brand GUSTAV HENSEL Model 20001497 Warranty 2 Years

Shipping & Returns

Photovoltaic installations require a reliable point of isolation between the generator and the grid, especially when maintenance or emergency shutdown is needed. The Hensel PV Disconnection Box 70 A Mi AE 3223 solves this by integrating a main circuit breaker and an NA-Schutz (grid and system protection) in a single, compact enclosure. This unit is engineered for three-phase PV systems up to 48 kW, ensuring safe disconnection and compliance with VDE-AR-N 4105.

Who is it for

This disconnection box is intended for solar installers, electrical contractors, and PV system operators who need a robust, code-compliant AC disconnection solution for commercial or residential photovoltaic arrays. It suits wall-mounted installations in outdoor or harsh environments where IP65 protection is essential.

Main features

  • Rated current 70 A, 3-pole, 400 V AC for three-phase PV systems
  • Integrated main circuit breaker with 10 kA breaking capacity
  • Built-in NA-Schutz (grid and system protection) compliant with VDE-AR-N 4105
  • IP65 polycarbonate enclosure, UV-resistant and suitable for outdoor use
  • Includes Type 2 surge protective device (SPD) for overvoltage protection
  • Wall-mounting design with metric knockouts for cable entry
  • Compliant with IEC 61439-2 for low-voltage switchgear assemblies

Specifications

  • Rated operational current (Ie): 70 A
  • Number of poles: 3
  • Rated operational voltage (Ue): 400 V AC
  • Rated insulation voltage (Ui): 690 V AC
  • Rated impulse withstand voltage (Uimp): 6 kV
  • Short-circuit breaking capacity (Icu): 10 kA
  • Protection class: IP65
  • Enclosure material: Polycarbonate (PC)
  • Enclosure series: Mi Series
  • Included components: Main circuit breaker, grid and system protection (NA-Schutz)
  • Grid protection standard: VDE-AR-N 4105 compliant
  • Mounting type: Wall mounting
  • Cable entry: Metric knockouts/flanges
  • Standards compliance: IEC 61439-2
  • Ambient temperature range: -25 °C to +40 °C
  • Max. PV generator power (approx.): Up to 48 kW (at 400V AC)
  • Overvoltage protection: Integrated Type 2 SPD (Surge Protective Device)

Tips

When installing, ensure the box is mounted on a flat, stable surface and that all cable glands are properly sealed to maintain the IP65 rating. For optimal performance, verify that the PV system's maximum current does not exceed 70 A and that the grid protection settings align with local utility requirements.

Specifications
Box contents
Main circuit breaker, grid and system protection (NA-Schutz), Type 2 SPD
Brand
GUSTAV HENSEL
Category
PV Disconnection Box
Certification
IP65
Compatibility
Three-phase PV systems up to 48 kW
Compliance certificates
VDE-AR-N 4105, IEC 61439-2
EAN
4012591134213
Input current
70 A
Model
PV Disconnection Box 70 A Mi AE 3223 3-Pole with Circuit Breaker and Grid Protection
MPN
20001497
Weight
12.5 kg
Price history over the last 6 months
Hensel PV Disconnection Box 70 A Mi AE 3223 3-Pole with Circuit Breaker and Grid Protection